Name | Description | Type | Additional information |
---|---|---|---|
PingRecordID |
The ping record ID shared with the telemetry record |
integer |
None. |
ZoneSafeSwitchChannel1In |
Zone Safe Signal Input 1 |
boolean |
None. |
ZoneSafeSwitchChannel2In |
Zone Safe Signal Input 2 |
boolean |
None. |
LifterType |
Whether the lifter information is from a left, right, trade or pick arm lifter |
integer |
None. |
Status |
Lifter unit status |
integer |
None. |
Position |
Lifter unit position |
decimal number |
None. |
BinCounter |
Lifter unit bin counter |
integer |
None. |
ControllerRequest |
Lifter Unit Body Controller Request |
integer |
None. |
EmergencyStop |
Lifter is stopped by activated emergency stop signal. |
boolean |
None. |
TruckInReverse |
Truck in reverse gear detected. |
boolean |
None. |
HopperPlateSwitch |
Lift is stopped by hopper plate switch , position hopper-plate detected as not safe. |
boolean |
None. |
EmergencyStopAndNeutralGearDetected |
Activated emergency stop signal and neutral gear detected. |
boolean |
None. |
WaitForPacker |
Lifter is stopped by packer signal and wait for moving till packer start signal is detected as safe. |
boolean |
None. |
LowVoltageStartVehicle |
Low voltage detected. |
boolean |
None. |
TruckBodyMaximumWeightStop |
Lifter is stopped by weight system signalling the maximum body weight reached signal. |
boolean |
None. |
TruckTooSlant |
Lifter is stopped by weighing system truck too slant signal. |
boolean |
None. |
FootboardStop_NotSafe |
Lifter is stopped by detection foot not safe ( occupied ) |
boolean |
None. |
WashingSystemOutOfPosition |
Lifter is stopped by signal the washing system is not on position. |
boolean |
None. |
ServiceRequired |
Terberg system (SBC10) reached service required date. |
boolean |
None. |
FootboardPenalty |
Illegal use of footboard and riding handle detected. Timer activated for penalty. |
boolean |
None. |
LifterNotReady |
Controller unit detected as not ready. |
boolean |
None. |
RidingHandleOut |
RIDING HANDLE OUT |
boolean |
None. |
CompactionUnitCANbusOffline |
Compaction unit CAN bus communication error. Not able to move lifter till CAN bus communication is stable. |
boolean |
None. |
ReverseRaiseError |
Lifter chair is not on the reverse raise position , while vehicle is in reverse gear. |
boolean |
None. |
LowSpeedCheckOilSupply |
Low speed of the lifter detected |
boolean |
None. |
FootboardErrorInputNotSafe |
Lifter stops by footboards inputs not safe detection. |
boolean |
None. |
IdentStop |
Lifter raise stopped by identification system. |
boolean |
None. |
AreaProtectionError |
Person or object detected by area protection sensors. |
boolean |
None. |
AreaProtectionSensorFault |
Person or object detected by area protection sensors. |
boolean |
None. |
SafetyArmError |
Lifter stop safety arms are not in the correct position |
boolean |
None. |
FootboardStop_FootboardOccupied |
Lifter stop by footboard occupied detection. |
boolean |
None. |
BinTooHeavy |
Bin is too heavy to lift |
boolean |
None. |
RequestToActivatePanelOtherSide |
Request to activate panel other side. Lifter button box side selection. |
boolean |
None. |
BinNotInDrivePosition |
The Bin lift is not in 'Drive position' , auto raise pending? |
boolean |
None. |
StartCompactionCycleRequest |
Start Compaction Auto cycles from lifter request. |
boolean |
None. |
PotentialBinCompactorCollisionPosition |
Collision control bit |
boolean |
None. |
InstantaneousFlowRequestForEcoMode |
Instantaneour lifter flow request for Eco mode |
boolean |
None. |